Quality Assurance

We follow a comprehensive Quality Assurance Plan (QAP) for wires and cables which involves raw material inspection, in-process monitoring, and final testing according to standards like IS/IEC. Key checks include conductor resistance, insulation thickness, spark tests, and sheath integrity, ensuring compliance with specifications such as tensile strength, elongation, and flame resistance.

QUALITY ASSURANCE PLAN
Material / Process Characteristic Tests Method of check / Test Equipment Sampling Plan Requirement / Ref. Document Internal Acceptances Norms
I. RAW MATERIAL
A. CONDUCTOR (COPPER) 1) Diameter Vernier caliper / Micrometer Each bobbin / Drum As per IS - 8130 As per IS - 8130
2) Surface finish Visual Each Drum The conductor should be smooth. Conforms to the requirement
3) Annealing Test (for copper) Tensile Testing M/c Random Drum As per IS - 8130 As per IS - 8130
4) Conductor Resistance at 20°C Digital micro ohm Meter Each Drum As per IS - 8130 As per IS - 8130
B. PVC COMPOUND INSULATION / SHEATH 1) Type of compound Visual check Random Lot Material grade as per Requirement As per Manufacturer specification
2) Tensile strength Before and After Ageing Review M.T.C Each Lot As per IS - 5831 As per IS - 5831
3) Elongation Before and After Ageing Review M.T.C Each Lot As per IS - 5831 As per IS - 5831
4) Thermal Stability Thermal stability oven Random Lot As per IS - 5831 As per IS - 5831
II. INPROCESS (SEMI FINISHED CABLES / WIRES) INSPECTION
A. BUNCHING / STRANDING 1) No of wires / Strand Self Device Measurement at the start of each job As per IS - 8130 As per IS - 8130
2) Diameter of Wire / Strand Vernier caliper / Micrometer Measurement at the start of each job As per IS - 8130 As per IS - 8130
3) Direction of Lay Visual Measurement at the start of each job As per requirement Conforms to the requirement
4) Overall Dimensions Vernier caliper / Micrometer Measurement at the start of each job As per requirement Conforms to the requirement
5) Conductor resistance Digital micro ohm Meter Measurement at the start of each job As per IS - 8130 As per IS - 8130
B. CORE EXTRUSION 1) Type of Compound Visual check of grade Once when the new bag is opened for use As per requirement Conforms to the requirement
2) Thickness of Insulation Vernier caliper / Micrometer Each setting & twice in a shift As per IS - 694 As per IS - 694
3) Core Identification Visual Each setting & twice in a shift As per IS - 694 As per IS - 694
4) Diameter Check Vernier caliper / Micrometer Each setting & twice in a shift As per requirement Conforms to the requirement
5) Surface finish Visual Start and end of each setting & twice during the processing for that setting Should be smooth & free from porosity Should be smooth & free from porosity
6) Concentricity of PVC Visual Start and end of each setting As per IS - 694 Conforms to the requirement
7) Printing / marking (For single core) Visual Continuous monitoring As per requirement Conforms to the requirement
C. TEST ON CORE IN LABORATORY 1) Thickness of Insulation Vernier caliper / Micrometer Random check for each size & colour As per IS - 694 As per IS - 694
2) Concentricity of PVC Vernier caliper / Micrometer One for each size & colour (if changed) As per IS - 694 As per IS - 694
3) Tensile strength & Elongation Tensile testing m/c One sample for each size As per IS - 694 As per IS - 5831
4) Insulation resistance & Volume resistivity Million mega ohm Meter One sample for each size As per IS - 694 As per IS - 5831
D. LAYING UP (FOR MULTICORE FLEXIBLE) 1) Number / Sequence of cores Visual Each setting As per IS - 694 As per IS - 694
2) Identification Of Cores Visual Each setting As per IS - 694 As per IS - 694
3) Lay Direction Visual Each setting As per IS - 694 As per IS - 694
4) Lay Length Meter Scale Each setting As per requirement Conforms to the requirement
E. INNER SHEATH (FOR SIZE ABOVE 10.0 SQMM) 1) Type of PVC/Tape Visual check Random As per requirement Conforms to the requirement
2) Thickness of Inner Sheath Vernier caliper / Micrometer Each setting As per IS - 694 As per IS - 694
3) Surface finish Visual Each Drum Smooth surface Smooth surface
F. OUTER SHEATH 1) Type of PVC Visual check of grade used Once when the new bag is opened for use As per requirement Conforms to the requirement
2) Thickness of Outer sheath Vernier caliper / microscope Each setting As per IS - 694 As per IS - 694
3) Overall Diameter Vernier caliper Each setting As per IS - 694 As per IS - 694
4) Colour of sheath Visual Check on each Drum As per IS - 694 As per IS - 694
5) Embossing / Sequential Marking Visual Check on each Drum As per IS - 694 As per IS - 694
6) Cable Length Visual Check on each Drum As per requirement Conforms to the requirement
7) Surface Quality Visual Check on each Drum Smooth surface Finishing Smooth surface Finishing
8) —
9) High Voltage Test High voltage tester 100% As per IS - 694 Withstood all connection
III. FINISHED CABLE INSPECTION
A. ROUTINE TEST 1) Conductor Resistance Digital micro ohm Meter As per IS - 694 As per IS - 8130 As per IS - 8130
2) High Voltage Test High voltage tester As per IS - 694 As per IS - 694 As per IS - 694
B. ACCEPTANCE TESTS 1) Annealing test on Copper Tensile testing m/c As per IS - 694 As per IS - 8130 As per IS - 8130
2) Conductor resistance Digital micro ohm Meter As per IS - 694 As per IS - 8130 As per IS - 8130
3) Thickness of Insulation / Sheath Vernier caliper / Micrometer As per IS - 694 As per IS - 5831 As per IS - 5831
4) Tensile strength of insulation / sheath Tensile testing m/c As per IS - 694 As per IS - 5831 As per IS - 5831
5) Elongation of insulation / sheath Tensile testing m/c As per IS - 694 As per IS - 5831 As per IS - 5831
6) Insulation Resistance Test / Volume resistivity Million mega ohm Meter As per IS - 694 As per IS - 5831 As per IS - 5831
7) High Voltage Test at room temp High voltage tester As per IS - 694 As per IS - 694 As per IS - 694
8) Flammability Test Flammability Chamber As per IS - 694 As per IS - 694 As per IS - 694
C. TYPE TEST 1) Annealing test on Copper Tensile testing m/c One Sample Per Lot As per IS - 8130 As per IS - 8130
2) Conductor At 20°C resistance Digital micro ohm Meter One Sample Per Lot As per IS - 8130 As per IS - 8130
3) Thickness of Insulation / sheath Vernier caliper One Sample Per Lot As per IS - 5831 As per IS - 5831
4) Tensile strength of insulation / sheath Tensile testing m/c One Sample Per Lot As per IS - 5831 As per IS - 5831
5) Elongation of insulation / sheath Tensile testing m/c One Sample Per Lot As per IS - 5831 As per IS - 5831
6) Ageing in air oven Ageing oven One Sample Per Lot As per IS - 5831 As per IS - 5831
7) Shrinkage test on insulation / sheath Hot air oven One Sample Per Lot As per IS - 5831 As per IS - 5831
8) Hot deformation test for insulation / sheath Hot air oven One Sample Per Lot As per IS - 5831 As per IS - 5831
9) Loss of mass test for sheath Weighting balance One Sample Per Lot As per IS - 5831 As per IS - 5831
10) Heat shock test for sheath Hot air oven One Sample Per Lot As per IS - 5831 As per IS - 5831
11) Thermal Stability Test for sheath Thermal Stability Oven One Sample Per Lot As per IS - 5831 As per IS - 5831
12) Insulation resistance and Volume resistivity Million mega ohm Meter As per IS - 7098 (PT-1) As per IS - 5831 As per IS - 5831
13) High Voltage Test at room Temperature HV tester One Sample Per Lot As per IS - 694 As per IS - 694
14) Cold bend / Cold Impact test Cold chamber One Sample Per Lot As per IS - 5831 As per IS - 5831
15) Flammability Test Flammability Chamber One Sample Per Lot As per IS - 694 As per IS - 694